System Control Using Monitor Control Software (MCS)
The MCS (Monitor Control Software) is an interface that congures
the QtPro over a LAN/network connection. The MCS software is
operated from any network browser. Below are the instructions to
connect to the control module over Ethernet locally and over the
network.
After the discussion on connecting to the control module, the MCS
screens will be discussed.
Connecting to the Qt 300/600 over Ethernet
1. System software is operated from any network browser. Software
is pre-installed in the control module. The HELP function
provides comprehensive software control operating instructions.
2. Connect a computer or the network to the 10/100 Ethernet jack.
3. Power the control module on by plugging it into a standard wall
outlet.
4. Press the right arrow on the control module to advance to the IP
address screen. An assigned IP address is displayed on the front
panel within two minutes of powering the module.
5. Access the Qt System Monitoring and Control Software
a. Read the control module Hostname or IP address
from the front control panel.
b. Enter either the hostname or IP address into the
browser address bar.
c. A prompt will appear requiring a username and
password.
d. The default username is “admin”. The default
password is “secret”.
6. After logging in with the defaults, you may change the
hostname, username and password.
DHCP Support
The system uses DHCP to obtain an IP address.
The system displays its MAC address on the front panel. This allows
the network administrator to use the MAC address to congure
the DHCP server to deliver a xed (static) IP address to the control
module.