page 27
Errors
If the control module is operating properly, software will display
“Status: Ok”. If the control module encounters an error, software will
display “Status: Error”. Click on “Error” to obtain additional informa-
tion. Click on “acknowledge” to clear the error (see Administration:
Notication of Errors, page 28). If the error condition persists, the
error will be signaled again after clearing the error.
WARNING: If a “System Thermal Fault” occurs, be sure that the
control module is not exposed to conditions beyond its ambient air
specication of 104°F, 40°C.
WARNING: In order to protect the electronic circuitry from damage,
the control module introduces a delay after experiencing an amp
short before turning the amp back on. A persistent short will result in
the amp being turned off once again. Shorts are most likely to occur
during installation of the system due to termination mistakes by the
installer. Shorts are unlikely once the control module is operational.
MCS: Administration Section
The following section will use gure 14 for reference.
Figure 14: Administration Section
IMPORTANT: Only update one block at a time and press Submit!
Changes to blocks that are not submitted will be lost if a different
block is submitted.